top of page
AdobeStock_352149697.jpeg

Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers

Cite

Full Text Link

Review

-

Structural and chiropractic

J Man Manip Ther.2022 Nov 15;1-9.

Authors:

L M Gorrell, A Sawatsky, W B Edwards, W Herzog

Abstract.

Background: The vertebral artery (VA) may be stretched and subsequently damaged during manual cervical spine manipulation. The objective of this study was to measure VA length changes that occur during cervical spine manipulation and to compare these to the VA failure length. Methods: Piezoelectric ultrasound crystals were implanted along the length of the VA (C1 to C7) and were used to measure length changes during cervical spine manipulation of seven un-embalmed, post-rigor human cadavers. Arteries were then excised, and elongation from arbitrary in-situ head/neck positions to first force (0.1 N) was measured. Following this, VA were stretched (8.33 mm/s) to mechanical failure. Failure was defined as the instance when VA elongation resulted in a decrease in force. Results: From arbitrary in-situ head/neck positions, the greatest average VA length change during spinal manipulation was [mean (range)] 5.1% (1.1 to 15.1%). From arbitrary in-situ head/neck positions, arteries were elongated on average 33.5% (4.6 to 84.6%) prior to first force occurrence and 51.3% (16.3 to 105.1%) to failure. Average failure forces were 3.4 N (1.4 to 9.7 N). Conclusions: Measured in arbitrary in-situ head/neck positions, VA were slack. It appears that this slack must be taken up prior to VA experiencing tensile force. During cervical spine manipulations (using cervical spine extension and rotation), arterial length changes remained below that slack length, suggesting that VA elongated but were not stretched during the manipulation. However, in order to answer the question if cervical spine manipulation is safe from a mechanical perspective, the testing performed here needs to be repeated using a defined in-situ head/neck position and take into consideration other structures (e.g. carotid arteries).

Publication Date: 

2022 Nov

OEID: 

6272

Gorrell, ML., Sawatsky, A., Edwards, BW., Herzog, W. (2022) 'Vertebral arteries do not experience tensile force during manual cervical spine manipulation applied to human cadavers', J Man Manip Ther.2022 Nov 15;1-9.

Sponsored by 

logo-footer-k.png

Search    Explore    About    Join    Web Policy     Contact Us

Copyright © 2023 OsteoEvidence. All Rights Reserved.
 

bottom of page